RH56F1 Context
Market context
RH56F1 is a five-finger dexterous robotic hand from Inspire Robots with an all-metal integrated skeleton, tactile sensing and EtherCAT-based control.
- Target environment: Humanoid builders, robot arms, mobile manipulators and automation cells that need dedicated manipulation or motion hardware.
- Workflow context: Grasping, actuation, end-effector integration, force control, robot-arm tooling and humanoid manipulation.
- Customer context: Robot OEMs, integrators, labs and automation teams selecting motion or manipulation components.
- Deployment model: Commercial or available product positioned for customer use, integration or developer adoption.
- Commercial maturity: Publicly presented as commercial or available, with maturity depending on deployment scale and support coverage.
- Adoption constraints: Adoption depends on mechanical fit, control interface, force or torque needs, reliability, cost and supply availability.
- Market position: RH56F1 sits in the robot-component layer, supporting manipulation, actuation or end-effector integration.
- Adjacent products: AGILINK OmniHand, Linker Hand L20, Shadow Dexterous Hand, RobStride actuator modules
Workflow
Grasping, actuation, end-effector integration, force control, robot-arm tooling and humanoid manipulation.
Deployment environment
Humanoid builders, robot arms, mobile manipulators and automation cells that need dedicated manipulation or motion hardware.
Specifications
- Total degrees of freedom: 6
- Variants: left and right hand variants
- Variant Interfaces: RH56F1-E2 uses EtherCAT + RS485; RH56F1-E4 uses EtherCAT + CAN FD
- actuation and motion control: micro linear servo actuator based dexterous hand
- Construction: all-metal integrated skeleton
- Control Interface: EtherCAT + RS485 or EtherCAT + CAN FD
- Force Resolution: 0.1 N
- Four Finger Bend Speed: >107°/s
- Four Finger Fingertip Force: ≥10 N
- Joints Total: 12
- Manipulation: tactile-assisted anthropomorphic grasping
- Palm Closing Time: ≤0.8 s
- Power Consumption: 5 A @ 24V
- Repeatability Mm: ±0.2 mm
- Sensor Stack: tactile, force, position and temperature sensing
- Tactile Sensor Accuracy: 5% FS
- Tactile Sensor Range: 30 N
- Tactile Sensors: 8
- Thumb Bend Speed: >37°/s
- Thumb Fingertip Force: ≥15 N
- Thumb Lateral Rotation Speed: >155°/s
- Voltage: 24V to 48V
- Weight: 620 ± 10 g
Tags
- Peer Group: Robot hands, Dexterous robotic hand, Robot hand components
- Workflow: End-effector manipulation, Dexterous grasping
- Capability: Tactile Dexterity, Robotic grasping, Force control
- Stack Layer: Robot end-effector, Manipulation stack
- Commercial Stage: Commercial product
- Market Signal: Supply-chain enabler
View RH56F1 overview